This guide will share with you the at times troubling process of setting up the Ubiquiti NanoStation Loco devices. Ubiquiti is not great at making working user interfaces so this guide will share with you which settings to disable out of the box in order to allow the two devices to transmit and recive data between them. Ubiquity decided to enable certain half baked features that will not allow the device to connect using default settings.
Setting up the First Device (Master)
Step 1: Initial Set Up
- Plugin both devices using the POE
- Connect to the first Device by connecting an Ethernet cable to the LAN port on the POE adapter, then connect to the default gateway at
192.168.172.1 - Once at the default gateway, set up the general Time settings as well as setup a password for the device
Step 2: Set up the Master Device
This device will receive WAN access through an Ethernet plugged into the LAN
-
Then once at the main web page, Turn on BOTH Access Point and PTP Mode by toggling them on
-
Then Select a Channel Width, usually 20mhz works best
important, ensure that the channel width is the same for the MASTER and the SLAVE device -
Turn on Control Frequency List Mhz and select all frequencies from the box below the toggle switch
-
Configure an SSID
-
note: this is an internal use SSID and is not visible to connect to, aka: it does not matter what you name it, but it needs to be the same across both devices
-
Under Advanced un-select Calculate EIRP Limit
-
Set Time Zone from
-
Lastly click Save Changes
-
Disable ipv6 Connectivity
Step 3: Set up the Slave
-
Connect to your Slave Nano’s SSID and go to its default web gateway at
192.168.172.1
-
Then setup credentials for the Slave device like a password and Time Zone
-
From the web portal, just enable PTP and do NOT enable access point mode
-
Make the SSID the same as the Master
-
Select a Channel Width, usually 20mhz works best
-
Turn on Control Frequency List Mhz and select ALL frequencies from the box below the toggle switch
-
Under Advanced un-select Calculate EIRP Limit
-
Disable ipv6 Connectivity
-
At this point from the main page you should see the two devices talking to each other
Step 4: Help it’s not working
The steps mentioned here is everything that is supposed to make them work, but sometimes they do not communicate to each other, if that is the case here are some things to check:
- 1: Are both devices set to the same channel width? Make sure that both devices are on the same channel width like 20Mhz or 10MHz, they both need to be the same
- 2: Is the SSID the same on both devices? The SSID needs to be the same name on both devices in order to get them to talk to each other
- 3: Is one device in AP and PTP and the other just has PTP enabled? One device should be an AP (access point) and have PTP enabled whereas the other device should just have PTP enabled
- 4: Is Calculate EIRP Limit disabled on both devies?
- 5: Are both devices on the same Firmware Version? For some reason they will not work if both devices are not on the same Firmware Version
- 6: Are the same frequencies selected on the Master and Slave device? Typically it is recommended to just simply select all frequencies to avoid this being an issue.

